Ex2000 is perfectly suited for fan and pump applications. It can handle loads up to 450 kW, and is engineered to keep your machine operating at optimum efficiency – even in the hot, humid and dusty conditions that characterize India's industrial environment. It has features that save energy and cost, and is easy to operate.
Range:
Enclosures:
Features:
- /F Control, Sensorless Vector Control, Slip Compensation
- Starting Torque: 200% at 0.5Hz for Sensorless Control
- Conformal Coating complying to IEC 60721-3-3 class 3C2
- Built-in RS485 Modbus
- Built-in Booster pump control
- Dual PID
- Pre-heat Function
- Reverse Rotation Prevention
- Component Life Monitoring
- Built-in DC Reactor from 22kW to 280kW
Dual rating operation:
Designed for heavy and normal duty applications.
Overload capacity
- Heavy duty operation: 150% of rated current for 60 sec
- Normal duty operation: 110% of rated current for 60 sec
Booster Pump
- It is used when a single drive is used to control multiple motors in pump systems, by default 4 Pumps can be controlled & Max up to 8 pumps can be controlled
- Precise Control of pressure
- Ideal cost effective solution for constant pressure / constant flow pumping application
PID & Dual PID
- In the centrifugal fan and pump, PID control is provided as a standard function in order to maintain a constant pressure, flow or level
- Where external or cascaded PID control is required, the built-in dual PID algorithm of the Ex2000 can be utilised to satisfy various system requirements
Sleep & Wake Function
- It automatically switches OFF Drive during user-programmed low- load conditions and then to start-up again when process demand increases
- It helps eliminate unnecessary operation at idle speeds, thus saving wear and tear, as well as energy
- PID Control
Automatic Energy Saving
- Load change may incur energy losses. But the optimised flux control of the Ex2000 results in more outstanding energy-saving
Pre Heat Function
- It allows the drive to maintain residual heat in the motor, which helps eliminate condensation in damp conditions when the motor is not in use.
- In the drive, an adjustable, low-level DC current is applied to the stator windings either continuously or on a duty cycle basis
KEB
- During power dips or momentary power outage, the Drive’s output can be maintained by utilising the residual mechanical energy in the load as a regenerative source.
- The duration of the power-dip ride-through depends on the load characteristics
Removable Terminal Block
- In case of AC Drive failure, control card of the existing drive can be replaced to new drive with wiring
Reduces the downtime of AC Drive replacement