Test Parameters | Specification |
---|---|
Rated Voltage |
250V AC/DC |
Minimum Applicable Load | 5V AC/DC, 1mA |
Terminal Style | 110 solder/quick connect |
Operating Humidity | 45 to 85% RH |
Contact Resistance | 50M Ω maximum |
Vibration Resistance | 10 to 55Hz, amplitude 1.2mm p-p |
Contact Configuration | Single pole, double pole |
Thermal Current | 5A |
Operating Temperature | -25°C to +55°C |
Degree of Protection | >10g |
Insulation Resistance | 100M Ω minimum (500V DC megger) |
Mechanical Life | Maintained : 1,000,000 operations minimum Momentary: 1,000,000 operations minimum Selector/Keylock : 250,000 operations minimum Switch unit : 2,000V AC, 1min between live/dead part and terminals of different poles; 1,000V AC, 1 minute between terminals of the |
Electrical Life | 100,000 operations minimum (at full rated load) |
Contact material | Gold-plated silver |