Dual Source Energy Meter - EM3490DS

Dual Source Energy Measurements

Rish EM 3490 DS features two energy integrator Utility & Generator. In normal operation meter accumulates energy counts in utility register & when utility shutdowns and control input signal of (10 to 60V DC/ 20 to 300V AC) is present on generator sensor energy starts accumulating in Generator register.

On site programmable PT/CT ratios

It is possible to program primary of external potential Transformer (PT), primary of external Current Transformer (CT) on site locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485)

User selectable PT Secondary

The secondary of external potential Transformer (PT) can be programmed on locally via front panel keys by entering into Programming mode or remotely via MODBUS (Rs485)

User selectable 3 phase 3W or 4W

User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485). For single phase applications, single phase version is available.

Low back depth

The instrument has very low back depth (behind the panel) of less than 80 mm in spite of optional features like pulse output Onsite

Selection of Auto scroll / Fixed Screen

User can set the display in auto scrolling mode or fixed screen mode locally via front panel keys by entering into Programming mode or remotely via MODBUS (RS485).

True RMS measurement

The instrument measures distorted waveform up to 15th Harmonic.

High brightness 2 line 7 digits LED display

Simultaneous displays Utility and Generator parameters.

Parameter Screen recall

In case of power failure, the instrument memorizes the last displayed screen. The displayed screen will get memorized only if user keeps this screen for minimum 40 sec duration before power failure for fixed screen mode.

User Assignable Registers for MODBUS

Customer can assign MODBUS register address as per his need for faster response time.

Energy Count storage

In case of power failure, the instrument memorizes the last energy count. Every 40 sec, the instrument updates the energy counter in the non-volatile memory.

Hour Run, ON Hour, Number of Interruptions

Hour run records the number of hours load is connected. ON Hour is the period for which the auxiliary supply is ON. Number of Interruptions indicates the number of times the Auxiliary Supply was interrupted. All these parameters are displayed in both utility & generator mode.